Journal Articles

Analysis by hazard plotting on steam generator tube leak in sodium-cooled fast reactors Phenix and BN600

Kurisaka, Kenichi

Proceedings of 30th International Conference on Nuclear Engineering (ICONE30) (Internet), 10 Pages, 2023/05

This study aims to understand a time trend of the occurrence rate of steam generator (SG) tube leak in the existing sodium-cooled fast reactors (SFRs) based on the observed data. The target on SFRs in the present paper is Phenix in France and BN600 in Russia. From the open literature review, we investigated the number of tube-to-tube plate weld, the number of tube-to-tube weld, heat transfer area of tube base metal, operating time of SGs, dates when SG tube leak occurred, leaked location, corrective action after tube leak such as replacement of leaked module. Based on these observed data, time to leak is estimated and then time trend of the occurrence rate of SG tube leak for each of the above-mentioned parts was quantitatively analyzed by the hazard plotting method. As a result, the rate of leak at tube-to-tube weld in Phenix shows increase with time due to probable cause of cyclic thermal stress in a short term. As for a long-term trend, the rate of tube leak in both Phenix and BN600 SGs indicated decrease with time probably thanks to improvement in welding and in SG operating condition and to removal of initial failure.

Journal Articles

Development of the severe accident evaluation method on second coolant leakages from the PHTS in a loop-type sodium-cooled fast reactor

Yamada, Fumiaki; Imaizumi, Yuya; Nishimura, Masahiro; Fukano, Yoshitaka; Arikawa, Mitsuhiro*

Proceedings of 25th International Conference on Nuclear Engineering (ICONE-25) (CD-ROM), 10 Pages, 2017/07

The loss-of-reactor-level (LORL) is one of the loss-of-heat-removal-system (LOHRS) of beyond-DBA (BDBA) severe accident. An evaluation method for the LORL which is caused by the coolant leakage in two positions of the primary heat transport system (PHTS) was developed for prototype JSFR which is loop-type sodium-cooled fast reactor. The secondary leakage in cold standby which occurred in different loop from that of the first leakage in rated power operation can lead LORL by excessive declining of the sodium level. Therefore, the sodium level behavior in RV was studied in a representative accident sequence by considering the sodium pumping up into RV, siphon-breaking to stop pumping out from RV and maintain the sodium level, and calculation programs for the transient sodium level in RV. The representative sequence with lowest sodium level was selected by considering combinations of possible leakage positions. As a result of the evaluation considering the countermeasures above, it was revealed that the LOHRS can be prevented by maintaining the sodium level for the operation of decay heat removal system, even in the leakages in two positions of PHTS which corresponds to BDBA.

JAEA Reports

Water flow simulation of the flow-induced vibration phenomenon of the thermowell in the prototype-FBR Monju

Anoda, Yoshinari; *; ; Murata, Hideo

JAERI-Tech 96-028, 71 Pages, 1996/06

JAERI-Tech-96-028.pdf:3.04MB

no abstracts in English

Journal Articles

Leakage test of worn respirators by Sodium-chloride particles

; ;

Hoken Butsuri, 11(1), p.45 - 50, 1976/01

no abstracts in English